
High-flex DC cable for single-axis trackers, where the cable moves every day and the sheath takes the abrasion.
A tracker moves from east to west every day for 25 years. Cable that is simply clipped to the structure will fail at the moving joint, so tracker harnesses use a fine-strand conductor, a torsion-capable lay length and a sheath that resists abrasion against the steel. ZMS supplies tracker cable as cut lengths or as pre-assembled harnesses with connectors fitted.
| Rated voltage | 0.6/1 kV · 1.5 kV DC |
|---|---|
| Conductor | Tinned copper, Class 6 |
| Insulation | XLPE / XLPO |
| Sheath | PUR or XLPO |
| Torsion | ±90 ° per metre |
| Flex life | Up to 5 million cycles |
| Temperature | −40 °C to +90 °C |
| Flame | IEC 60332-1-2 |
| Standard | EN 50618, IEC 60228 |
| Packing | Coils, reels and harness sets |
Typical values. Final construction is confirmed on the order datasheet.
Request This ProductTell us the system voltage, conductor size, length and destination. We can prepare a construction drawing and sample for review.
Phone: +86 371 6782 9333
WhatsApp: +86 173 0383 6349
Email: sales@zmscable.com
Cable is packed so it can be pulled without a re-reel, and documented so the site team can match each drum to the test report.
Wooden or steel-wooden drums for constructions above 16 mm², with lagging and a PE wrap. Drum diameter is selected so the cable is not bent below its minimum bending radius.
Small sizes and short lengths are supplied as coils in cartons or on pallets, wrapped and labelled with the same drum numbers used in the packing list.
Continuous length is measured during rewinding, and the delivered length is stated on the drum plate and the packing list. Short-length tolerance is agreed in the order.
Each drum is marked with product description, size, voltage rating, standard, length, gross weight, drum number and the project or PO reference.
Drum layout and quantity per 20′ or 40′ container are planned by diameter and weight; a loading plan is issued before shipment.
Commercial invoice, packing list, bill of lading and certificate of origin are issued for the shipment; FOB, CIF and DAP terms are quoted on request.
| Packing | Wooden / steel-wooden drum, coil or carton |
|---|---|
| Standard length | 500 m, 1000 m or as agreed |
| Drum marking | Product, size, length, standard, PO no. |
| Documents | Test report, packing list, CO, B/L |
| Lead time | Typically 15–25 working days |
Lead time is confirmed on the order acknowledgement and starts after drawing approval.
Compare voltage, screen and sheath options before you specify.

Single-core PV DC cable with XLPE insulation and cross-linked sheath for module-to-inverter wiring.
Technical details →
Flexible tinned copper earthing conductor for array frames, tracker piles and inverter bonding.
Technical details →Five product families, seven core products and custom constructions for project-specific requirements.
Browse all products →Send us the system voltage, route and environment. We will recommend the construction and quote factory-direct.
Share the system voltage, conductor size, cable length, installation route, sheath or armour requirement and delivery destination. Our engineering team will reply within one business day.