Energy storage cable for racks, PCS and BMS wiring

High-flex, LSZH cable for battery cells, racks, PCS and the DC bus of a containerised storage plant.

Home / Products / Energy Storage Cables
Energy storage cable for battery racks, PCS and BMS wiring
Class 6High-flex conductor
Range overview

Energy Storage Cables

A battery storage plant runs current in both directions, all day, at a duty cycle no other cable in the project sees. Terminations sit inside enclosures where smoke and halogen content matter if a cell fails. ZMS energy storage cable uses fine-strand tinned copper, XLPO insulation and a low-smoke halogen-free sheath, with the flexibility needed to dress connections inside a rack.

System voltage1500 V DC
ConductorClass 6 tinned copper
SheathLSZH
StandardEN 50618 / IEC 62930
Technical data

Energy Storage Cables specification

Rated voltage0.6/1 kV AC · 1.5 kV DC
ConductorTinned copper, Class 6
InsulationXLPO, cross-linked
SheathLSZH, low smoke halogen free
Cross-section16–400 mm²
Temperature−40 °C to +105 °C (125 °C short term)
FlameIEC 60332-1-2, IEC 60332-3-24
Smoke / halogenIEC 61034-2 · IEC 60754-1/-2
StandardEN 50618, IEC 62930, IEC 60228
Packing500 m / 1000 m drums, cut lengths on request

Typical construction data. Final values are confirmed on the order-specific datasheet.

Customisation

We can adapt this family to the project requirements. Common options include:

  • Orange, black or red sheath
  • Screened construction for BMS signals
  • Heat-shrink or lug pre-assembly
  • Parallel cable sets with matched length
  • 2000 V DC rating option
  • Fire-resistant variant for egress routes
Send Your Specification
Performance

Fire, smoke and cycling performance

Battery rooms and containers concentrate a large fault current in a small space. The cable has to stay flexible for tight rack routing while limiting flame spread and smoke, and it has to carry continuous charge and discharge cycling without conductor fatigue.

  • Flame propagation to IEC 60332-1-2
  • Smoke density to IEC 61034 and acid gas to IEC 60754
  • Class 5 or class 6 flexible copper for rack and PCS connections
  • LSZH sheath for container and indoor cabinet use

Selection guide

The energy storage cables selection guide covers voltage rating, conductor class, screen and sheath options, drum length and the test reports issued with each delivery.

Request the Selection Guide

Sent as a PDF for your project file.

Applications

Where energy storage cables are specified

The right construction depends on voltage, movement and the environment along the route.

Cell to rack connection

Short, high-current links inside the rack, where flexibility decides how fast a pack can be serviced.

Rack to PCS / DC bus

Longer DC runs between battery containers and the power conversion system, sized for voltage drop.

Auxiliary power feed

BMS, HVAC and fire-suppression supply inside the container, where LSZH performance is required.

Engineering support

Need help selecting energy storage cables?

Send the plant type, system voltage and installation route. We will confirm the construction and prepare a quotation.